Capacity | ΦA | B | ΦC | D | E | F | G | H | Weight(kg) |
---|---|---|---|---|---|---|---|---|---|
1.5tf~5tf | 118 | 46 | 40 | 3 | 8-Φ9 | 100 | 153 | M27×2 | 3 |
7tf,8tf | 144 | 55 | 40 | 7.5 | 8-Φ11 | 120 | 178 | M27×2 | 6 |
14tf | 157 | 64 | 40 | 12 | 8-Φ14 | 135 | 192 | M39×2 | 8 |
Specifications | Accuracy |
---|---|
Rated capacity(R.C.) | 1.5tf, 2tf, 3tf, 4tf, 5tf, 7tf, 8tf, 14tf |
Rated output(R.O.) | 2mV/V±0.1% |
Nonlinearity | 0.1% of R.O.(300~500tf:0.2%) |
Hysteresis | 0.1% of R.O.(300~500tf:0.2%) |
Repeatability | 0.05% of R.O.(300~500tf:0.1%) |
Zero balance | ±2% of R.O. |
Temperature effect, on rated output | 0.05% of LOAD/10℃ |
Temperature effect, on zero balance | 0.05% of R.O./10℃ |
Temperature range, compensated | -10~60℃ |
Temperature range, safe | -20~80℃ |
Terminal resistance input | 700 ±5Ω |
Terminal resistance output | 700 ±3Ω |
Insulation resistance bridge/case | 2000㏁ |
Excitation recommended | 10V |
Safe overload | 150% R.C |
Cable length | Φ7mm 4core, 3m |