Home / Product / Load Cells / Compression & tension type / UL

UL

    UL

      • Applicable for both compression and tension methods.
      • Being tough against twistion momentum, most suitable for load fatigue testing repeat test of load etc.
      • Hermetically sealed

       

      Dimensions

      unit:mm

      WIRING INFOMATION
      Capacity ΦA B ΦC D E F G H Weight(kg)
      500kgf (4.903KN) 88 25 22 1.5 6-Φ6.5 75 108 M12×12.5 1
      1tf (9.807KN) 118 46 43 1.5 8-Φ9 100 153 M18×1.5 3
      2tf (19.61KN)
      5tf (49.03KN)
      10tf (98.07KN) 178 65 43 11 8-Φ13 155 215 M24×2 9
      20tf (196.1KN) 178 65 43 11 8-Φ13 155 215 M39×2
      50tf (490.3KN) 226 100 43 28.5 12-Φ18 190 266 M50×2 23
      100tf (980.7KN) 310 130 43 43.5 16-Φ22 260 350 M76×3 60
      200tf (1961KN) 380 170 43 63 16-Φ38 315 420 M100×3 90
      300tf (2942KN) 450 200 50 75 16-Φ45 365 490 M140×3 180
      500tf (4903KN) 496 300 70 115 16-Φ52 420 536 M180×3 245
      1000tf(9800KN) Custom size
      Specifications
      Specifications Accuracy
      UL ULH
      Rated capacity(R.C.) 500kgf, 1tf, 2tf, 5tf, 10tf, 20tf, 30tf, 50tf, 100tf, 200tf, 300tf, 500tf 500kgf, 1tf, 2tf, 5tf, 10tf, 20tf, 50tf
      Rated output(R.O.) 2mV/V±0.1%
      Nonlinearity 0.05% of R.O.(300~500tf:0.1%) 0.02% of R.O.
      Hysteresis 0.05% of R.O.(300~500tf:0.1%) 0.02% of R.O.
      Repeatability 0.03% of R.O.(300~500tf:0.05%) 0.02% of R.O.
      Zero balance ±2% of R.O.
      Temperature effect, on rated output 0.05% of LOAD/10℃ 0.03% of LOAD/10℃
      Temperature effect, on zero balance 0.05% of R.O./10℃ 0.03% of R.O./10℃
      Temperature range, compensated -10~60℃
      Temperature range, safe -20~80℃
      Terminal resistance input 350 ±5Ω 800 ±50Ω
      Terminal resistance output 350 ±3Ω 700 ±3Ω
      Insulation resistance bridge/case 2000㏁
      Excitation recommended 10V
      Safe overload 150% R.C
      Cable length Φ7mm 4core, 3m
      Specifications are subiect to change without notice.