Home / Product / Load Cells / Compression & tension type / TX
Home / Product / Load Cells / Compression & tension type / TX
UL272
UL272
unit:mm
Capacity | ΦA | B | ΦC | D | E | F | G | H | Weight(kg) |
---|---|---|---|---|---|---|---|---|---|
1.5tf~5tf | 118 | 46 | 40 | 3 | 8-Φ9 | 100 | 153 | M27×2 | 3 |
7tf,8tf | 144 | 55 | 40 | 7.5 | 8-Φ11 | 120 | 178 | M27×2 | 6 |
14tf | 157 | 64 | 40 | 12 | 8-Φ14 | 135 | 192 | M39×2 | 8 |
Specifications | TXH | TXM | TXG |
---|---|---|---|
Rated capacity(R.C.) | 1tf, 2tf, 3tf, 5tf, 10tf, 20tf | 100kgf, 200kgf, 500kgf, 1tf, 2tf, 3tf, 5tf, 10tf, 20tf |
100kgf, 200kgf, 500kgf, 1tf, 2tf, 3tf, 5tf, 10tf, 20tf, 50tf, 100tf |
Rated output(R.O.) | 2.0mV/V±0.1% | 2.0mV/V±0.1% (50tf~500tf 1.5mV/V) | |
Nonlinearity | 0.02% of R.O. | 0.05% of R.O. | 0.1% of R.O. |
Hysteresis | |||
Repeatability | |||
Zero balance | ±1% of R.O. | ||
Temperature effect, on rated output | 0.03% of LOAD/10℃ | 0.1% of LOAD/10℃ | |
Temperature effect, on zero balance | 0.03% of R.O./10℃ | 0.1% of R.O./10℃ | |
Temperature range, compensated | -10~60℃ | ||
Temperature range, safe | -20~80℃ | ||
Terminal resistance input | 350±5Ω | ||
Terminal resistance output | 350±5Ω | ||
Insulation resistance bridge/case | 5000㏁ | ||
Excitation recommended | 10V | ||
Safe overload | 150% | ||
Cable length | Φ7.5mm 4core,3m |