Home / Product / Load Cells / Compression & tension type / TB

TB

    TB

      Model TB load cells measure both tension & compression load force. Applications include performance testers for automotive industry.
      Dimensions

      unit:mm

      Capacity A B C D ΦE ΦF G H Weight(kg)
      1tf (9.807KN) 75 25.5 24.5 25 30 28 M20*1.5 DP20 M20*1.5 2
      2tf (19.61KN) 75 25.5 24.5 25 30 28 M20*1.5 DP20 M20*1.5
      5tf (49.03KN) 173 30 100 43 55.5 42 M27*1.5 DP40 M27*1.5 3
      10tf (98.07KN) 173 30 100 43 62.5 42 M27*1.5 DP40 M27*1.5
      20tf (196.1KN) 195 62.5 87.5 45 62.5 52 M33*2 DP53 M33*1.5 5
      50tf (490.3KN) 295 50 190 55 120 78 M48*2 DP55 M48*2 15
      100tf (980.7KN) 355 80 200 75 176 116 M72*6 DP75 M72*6 35
      150tf (1471KN) 385 125 170 90 150 130 M90*6 DP90 M90*6 30
      200tf (1961KN) 465 135 220 110 190 170 M110*6 DP115 M110*6 58
      300tf (2942KN) 496 143 200 153 215 185 M125*4 DP125 M125*4 80
      Specifications
      Specifications Accuracy
      Model TB
      Rated Capacity (R.C) 1tf , 2tf , 5tf , 10tf , 20tf , 50tf , 100tf , 150tf , 200tf , 300tf
      Rated Output (R.O)

      1 ~ 20tf : 1mV/V ± 2%

      50~300tf : 1.5mV/V ± 2%

      Nonlinearity 0.15% of R.O.
      Hysteresis 0.15% of R.O.
      Repeatability 0.15% of R.O.
      Zero balance ±1% of R.O.
      Temperature range, compensated -10 ~ 50℃
      Temperature range, safe -20 ~ 70℃
      Tmperature effect, on rated output ±0.03% of LOAD/10℃
      Temperature effect, on zero balance ±0.03% of R.O./10℃
      Terminal resistance input 350 ± 3.5Ω
      Terminal resistance output 350 ± 5Ω
      Insulation resistance bridge/case 2000MΩ
      Cable length Φ7, 4CORE SHIELD CABLE, 3m
      Excitation recommended 10V
      Safe overload 150% R.C
      Specifications are subiect to change without notice.