Home / Product / Load Cells / Compression & tension type / CWW11

CWW11

    CWW11

      • These load cells are extremely Slim and lightweight.
      • Easy installation with hole in center.
      • Designed for use in civil engineering measurement, these loads on tunnel supports and soil pressure on protective Walls to aid control in construction projects.

       

      Dimensions

      unit:mm

      WIRING INFOMATION
      Dimensions Table
      Capacity ΦA ΦB ΦC D E F G H
      50kg1 (490.3N) 10 55 22 15 2 48 16 2×4-M4 DP6
      100kgt (980.7N) 10 55 22 15 2 48 16 2×4-M4 DP6
      200kgf (1.961kN) 10 55 22 15 2 48 16 2×4-M4 DP6
      500kgf (4.903kN) 10 55 22 15 2 48 16 2×4-M4 DP6
      1tf (9.807kN) 12 68 28 20 1.5 60 20 2×4-M4 DP6
      2tf (19.61kN) 12 68 28 20 1.5 60 20 2×4-M4 DP6
      3tf (29.42MN) 12 68 28 20 1.5 60 20 2×4-M4 DP6
      5tf (49.03kN) 12 68 28 20 1.5 60 20 2×4-M4 DP6
      10tf (98.07kN) 50 148 80 37 5 132 65 2×6-M4 DP6
      Specifications
      Specifications Accuracy
      Rated capacity(R.C.)

      50kgf ~ 500kgf (490.3N ~ 4.903kN)

      1tf ~ 10tf (98.07kN ~ 98.07kN)

      Rated output(R.O.) 1.5mV/V æ0.4%
      Nonlinearity 1% of R.O.
      Hysteresis 1% of R.O.
      Repeatability 0.5% of R.O.
      Zero balance 0.5% of R.O.
      Terminal resistance, input 700±10Ω
      Terminal resistance, output 700±5Ω
      Insulation resistance bridge 2000Ω
      Temperature range, compensated -10~60℃
      Temperature range, Safe -20~80℃
      Temperature effect on zero balance 0.1% R.O./10℃
      Temperature effect on rated output 0.05% R.O./10℃
      Excitation recommended 10V
      Safe overload 150% R.C.
      Cable length

      5gt5W – 05mm 4ce, 3m

      10tf – 07mm 4core, 3m

      Specifications are subiect to change without notice.