Home / Product / Load Cells / Compression & tension type / CWW

CWW

    CWW

      • These load cells are extremely Slim and lightweight.
      • Easy installation with hole in center.
      • Designed for use in civil engineering measurement, these loads on tunnel supports and soil pressure on protective Walls to aid control in construction projects.

       

      Dimensions

      unit:mm

      WIRING INFOMATION
      Dimensions Table
      Capacity ΦA ΦB ΦC D E Weight(kg)
      50kgf (490.3N) 10 55 22 15 2 0.5
      100kgf (980.7N) 10 55 22 15 2
      200kgf (1.961kN) 10 55 22 15 2
      500kgf (4.903kN) 10 55 22 15 2
      1tf (9.807kN) 12 68 28 20 1.5 0.7
      2tf (19.61kN) 12 68 28 20 1.5
      3tf (29.42kN) 12 68 28 20 1.5
      5tf (49.03kN) 12 68 28 20 1.5
      10tf (98.07kN) 50 148 80 37 5 3
      20tf (196.1kN) 70 155 99 43 5 6
      30tf (294.2kN) 70 155 99 43 5
      50tf (490.3kN) 70 155 99 43 5
      100tf (980.7kN) 110 198 129 43 5 8
      150tf (1.471MN) 165 278 200 50 8 20
      200tf (1.961MN) 170 308 212 65 10 27
      Specifications
      Specifications Accuracy
      Rated capacity(R.C) 50kgf, 100kgf, 200kgf, 500kgf, 1tf, 2tf, 3tf, 5tf,10tf, 20tf, 30tf, 50tf, 100tf, 150tf, 200tf
      (490.3N, 980.7N, 1.961kN, 4.903kN, 9.807kN, 19.61kN, 29.42kN, 49.03kN, 98.07kN, 196.1kN, 490.3kN, 980.7kN, 1.961MN)
      Rated output(R.O) 1.5mV/V±0.4%
      Nonlinearity 1% of R.O.
      Hysteresis 0.5% of R.O.
      Repeatability 0.5% of R.O.
      Zero balance 0.5% of R.O.
      Terminal resistance input 700 ±10Ω
      Terminal resistance output 700 ±5Ω
      Insulation resistance 2000Ω
      Temperature range, compensated -10~60℃
      Temperature range, Safe -20~80℃
      Temperature effect, on zero balance 0.1% R.O./10℃
      Temperature effect, on rated output 0.05% R.O./10℃
      Excitation recommended 10V
      Safe overload 150% R.C
      Cable length Φ7mm 4core, 3m
      Specifications are subiect to change without notice.