      Dimensions Table
      Capacity ΦA ΦB ΦC D E F G Weight(kg)
      500kgf (4.903KN) 10 24 40 50 18 2×4-M4 DP10 1 0.5
      1tf (9.807KN) 18 55 62 70 44 2×8-M5 DP10 2 1
      2tf (19.61KN) 18 55 62 70 44 2×8-M5 DP10 2 1
      3tf (29.42KN) 18 55 62 70 44 2×8-M5 DP10 2 1
      5tf (49.03KN) 18 55 62 70 44 2×8-M5 DP10 2 1
      10tf (98.07KN) 18 55 62 80 44 2×8-M5 DP10 2 1.3
      20tf (196.1KN) 43 68 96 80 56 2×8-M6 DP10 3 3
      50tf (490.3KN) 80 112 130 110 96 2×6-M8 DP10 3 11
      100tf (980.7KN) 85 118 158 110 102 2×6-M12 DP10 3 13
      200tf (1.961MIN) 120 162 240 120 140 2×6-M12 DP12 3 25
      300tf (2.942MIN) 120 179 240 120 150 2×6-M12 DP15 3 26
      500tf (4.903MIN) 150 227 265 200 190 2×12-M12 DP15 8 30
      Specifications
      Specifications Accuracy
      Rated capacity(R.C) 500kgf, 1tf, 2tf, 3tf, 5tf, 10tf, 20tf, 50tf, 100tf, 200tf, 300tf
      Rated output(R.O) 1mV/V±0.4%
      Nonlinearity 1% of R.O.
      Hysteresis 1% of R.O.
      Repeatability 0.2% of R.O.
      Zero balance ±2% of R.O.
      Temperature effect, on rated output 0.05% of LOAD/10℃
      Temperature effect, on zero balance 0.1% of R.O./10℃
      Temperature range, compensated -10~60℃
      Temperature range, safe -20~80℃
      Terminal resistance input 700 ±50Ω
      Terminal resistance output 700 ±2Ω
      Insulation resistance bridge/case 2000MΩ
      Excitation recommended 10V
      Safe overload 150% R.C
      Cable length Φ7mm 4core, 3m
      Specifications are subiect to change without notice.