Home / Product / Amplifier / Dynamic strain amplifier / DN-AM120
Home / Product / Amplifier / Dynamic strain amplifier / DN-AM120
DN-AM120
DN-AM120
unit:mm
Specifications | Accuracy |
---|---|
Bridge voltage | Constant voltage DC 5V, 10V |
Application sensor | Stain gauge sensor(100Ω ~ 1㏀) |
Rated output | Voltage 10V, Load resistance more than 200Ω Current 4~ 20mA, Load resistance less than 300Ω |
Zero adjustment range | 10%, 10 rotations |
Sensitivity adjustment range | 1500 Multiplier |
S/N rate | 51dB |
Answering frequency | DC ~ 20kHz (-3dB) |
Non-linearity | 0.02% F.S |
Operating temperature | -10~60℃ |
Protection class | IP66, EN60529 |
Power | DC 24V |